Download fiberizer desktop otdr trace viewer software. How much does the loss of a cable plant change with the different methods. Manual measurement offers two ways to measure event loss. Otdrs test the overall length, loss and optical return loss of fiber optic cables or networks. This indicates a very dangerous procedure that could result in serious injury or death if not performed properly. Select multi mode or single mode if otdr is a quad wavelength unit press to enter the menu mode. Removing otdr complexity with iolm traditional otdr trace methodical approach and expertise required multiple trace acquisitions commonly required manual interpretation and diagnosis iolm automated, dynamic multipulse acquisitions results combined into a single linear view all analysis combined into one linear view. An optical timedomain reflectometer otdr is an optoelectronic instrument used to characterize an optical fiber. To get a true measurement of an event with an otdr, a trace needs to be shot from both directions, and. A complete testing strategy download pdf fiber is playing as increasing role in most network installations, driven by the need for higherbandwidth applications in data centers and backbone cabling system, as well as emerging lowlatency 5g and fttx deployments in service provider networks. In many of my previous articles on fiber optic testing, i have mentioned optical timedomain reflectometers otdrs.
In that conversation, it was revealed that there were about 30 cables with a total of 1,000 fibers involved in the. Viavi smartotdr getting started manual pdf download. The otdr will display the distance from the otdr connector to the end of the fiber as well as the total loss of the span in db or the loss per kilometer. I have been personally involved in several instances where misapplication of otdr testing has cost. Our world class otdr modules continue this tradition with the latest in high performance hardware and dedicated, easy to use software.
Otdr handheld optical time domain reflectometry is a new generation of intelligent opticalfibre communication instrument. That caused another call, a conference call also involving the contractor, where we discussed the relevant testing standard and procedures for loss testing. Contact age technologies at 011 869392567 for more information on our otdrtr300 tester. The otdr basics poster provides a fundamental collection of technical information about otdrs and fiber testing. As we mentioned earlier, otdrs are always used on osp cables to verify the loss of each splice. The otdr test process is dependent on the equipment type and the fiber optic cable run being tested, as well as the objectives of the test. The function key on front panel, indicated by letter or icon in quotation marks, e.
I have been personally involved in several instances where misapplication of otdr testing. Otdr testing otdr testing procedures and equipment exfo. Do not download or install software that has not been specifically recommended or licensed by anritsu. The method shown is on the foa 1 page standard foa1 which you may print or download and insert in your documentation. Average per test method shows what different test crews would find results. Additionally, they detect, locate, identify and measure optical components in installed networks including fusion splices, optical connectors and pon splitters as well as faults such as breaks or tight bends causing high loss. The iolm lets you take advantage of the full power of your otdr, bringing automation to a new leveland enabling even the untrained technician to become a test expert in no time. Foa quickstart guides are short, simple guides to basic fiber optic tests. The viavi solutions hires multimode otdr solution has been designed to characterize and locate faults on very short multimode fiber runs deployed in aircraft, spacecraft, submarines, and ships. Utilizing sophisticated algorithms, the equipment is able to calculate exact length and approximate loss. It shows the difference in traces according to how one sets up the otdr test parameters.
During the process of otdr testing, the instrument injects a higher power laser or fiber optic light source pulse into a fiber from one end of the fiber cable, with the otdr port to receive the returning information. An outside plant installer will have an otdr on hand to test every splice made as its. Otdrs are valuable fiber optic testers when used properly. Once youve tested all the links and saved each record, you can download results to a.
An otdr is the optical equivalent of an electronic time domain reflectometer. When to use an otdr or lts kingfisher international. However, there are some common otdr testing procedures that are fundamental to any application. Acceptance testing of fiber optic cable using an otdr by.
The optical time domain reflectometer otdr is an essential tool used to test the integrity of fiber optic cables, which can be applied to evaluate the length of fiber cables, measure transmission and connection attenuation and to detect the fault location of fiber links as well. Testing a fiber optic cable plant this test will measure the loss of an installed fiber optic cable plant, singlemode or multimode, including the loss of all fiber, splices and connectors. View and download viavi smartotdr getting started manual online. View and download viavi smartotdr 100 user manual online. Integrated fiber characterization and dispersion test solution. An otdr requires much more technical expertise and training to use, and testing is generally much slower. Users manual for otdr iii safety terms used in this manual the warning sign denotes a hazard.
Innovation is front and center at exfo, and the intelligent optical link mapper iolm is a prime example of a gamechanging solution. Use the data storage features of the otdr to save the trace using a unique file name. This document includes basic testing procedures for verifying horizontal optical fiber. As opposed to the simple light source and power meter test method, the otdr can identify and locate any potential faults, macrobends or breaks that could impact network performance. Information in otdr traces notes insertion loss testing of the cable plant is recommended for acceptance testing. All are written in the same straightforward format. Demystifying fiber test methods mpo configurations fluke.
In premises applications, fiber optic cables can be used as the backbone cabling in a standard structured cabling network, connecting network hardware in the computer roommain cross connect. The cma5000a optical time domain reflectometer otdr application is based on over 30 years of development and experience in characterizing optical fibers. Record the date of the test, operator, test equipment used, cable and fiber identification, test wavelengths and all traces for the fiber under test. This test is commonly used to verify the quality of the installation and troubleshoot problems. Otdr testinggn netttest cma4000 otdrotdr optical time domain reflectometer technology is designed to provide a single ended test of any cable. Lets look at how an otdr works and see how it can help testing and troubleshooting. A test cable used to connect the otdr to the near end of the link under test that is long enough to allow the otdr to measure the loss of the first connection. With projx management system, optifiber pro allows a project manager to define each users role, settings and the associated tasks to be performed transforming the otdr into an allinone fiber testing tool complete with. In combination with an otdr unit, the mainframe can test for. Optical time domain reflectometer test fiber otdr s are useful for determination of overall cable quality. With projx management system, optifiber pro allows a project manager to define each users role, settings and the associated tasks to be performed transforming the otdr into an allin. Sep 14, 2012 this is an foa video showing how an otdr is used for testing optical fiber. Necafoa301 standard for installing and testing fiber optic cables.
Display features press tabs to perform the following. As the optical pulse is transmitted through the fiber, part of the scattered reflection will return to the otdr. The following example helps demonstrate how an extended test regime can help to ensure consistent quality during installation. Instructions of otdr test modes and parameters ftth. Based on these functions, it is commonly employed to fiber optical cable maintenance and construction. Not all cable plants are long enough for otdr testing. Connect a properly prepared reference cord to the power meter port and the light source port. Backscattering the scattering of light in a fiber back toward the source,used to. Oct 28, 2015 otdr handheld optical time domain reflectometry is a new generation of intelligent opticalfibre communication instrument. It can verify splice loss, measure length and find faults. Application note submarine cable testing mw90010a coherent otdr by stuart whitehead background with the submarine optical cable industry continuing to grow at a steady rate and the ever increase reliance on transcontinental data traffic, the importance of minimizing optical network downtime has become more critical than ever.
Making otdr measurements the fiber optic association. Otdr fiber visualizer fiber visualizer is a new fault location function designed to simplify the entire testing process. This is an foa video showing how an otdr is used for testing optical fiber. Field test procedure for optical fiber link measurements sterlite. Working principle and characteristics of otdr fs community. Wolszczak contact the authors jdsu 34 rue necker 42000 saintetienne france tel.
The optical time domain reflectometer otdr is useful for testing the integrity of fiber optic cables. If you need to know about fiber optic testing procedures, i suggest you download this document and study. Historically, lspm test sets require manual calculations and subjective interpretation by. Titled understanding otdrs, the course include a free otdr simulator that students can download for practice use. Unpinned to unpinned channel using the equipment cord method the equipment cord is the patch cord attached to the transceiver during normal transmission. Mt9083abc otdr fiber visualizer demonstration the access master mt9083 to provide an easytouse and reliable hand held unit designed for the field. Use the scroll wheel to highlight the lts function icon and press. Otdr testing of fiber optic cable plants otdr testing creates a snapshot of a fiber optic cable.
Optical dispersion measurement modules odm for tberdmts6000a, 8000 platforms. Innovation is front and center at exfo, and the iolm is a prime example of a gamechanging solution. An important aspect in maximizing an otdrs value is to properly plan its daytoday usage. Mainframe handheld otdr, designed for the construction, turnup and maintenance of fiber networks. Smartotdr measuring instruments pdf manual download. Standard for installing and testing fiber optic cables. Test results are downloaded and organized in the office computer. This method of measurement removes the attenuation between two. Which is widely used in the construction, maintenance, measurement, emergency repair of opticalfibre communication system works.
An otdr electrical tester is a fibre testing device that performs the following functions it extensively tests the competency of all types of network cabling. If the unit is a quad wavelength unit, ensure the proper port is connected. Otdr testing requires interpretation of the data acquired, called the trace or signature, by a skilled operator. Attenuation the opticalloss of fiber per unit coefficient length,expressed in dbkm.
Optical time domain reflectometer test fiber otdrs are useful for determination of overall cable quality. Cfo 301 standard for installing and testing fiber optics management, security or fire alarm systems, or any other communications link. One cable reference method has highest loss includes fut but also connectors on both side. So the labour expense of using an otdr may be considerably higher. The otdr can check for cable problems such as defective cables, splice problems, inadequate bend radius, fiber cable microcracks, etc. The measurement trace generated by the otdr is an integrated sum plot of the magnitude of light received from scattering locations along the length of the fiber. Extended or tier 2 testing involves the use of an otdr and an olts. The operating units in gui that can be clicked by stylus, indicated by letters in square brackets, e. It makes it possible to inspect, verify, certify and troubleshoot installed fibre cables. Improper use, however, can be misleading and, in my experience, can contribute to expensive mistakes for the contractor. Reference guide to fiber optic testing lasertec, center for. Download otdr trace viewer otdr viewer fiberizer cloud. Assume that the first connector in a 2connector, 100meter fiber link performs extremely well, while the second connector is poorly installed or. Guidance for otdr assessment of fusion spliced single.
It injects a series of optical pulses into the fiber under test. The timedependent backscattered power pbst received by the otdr detector from an input light pulse power p0 and pulse duration w is. Expert labour to operate an otdr may not be available in the required timescale, when a simpler loss test set can be operated faster and with lower skill levels. Reference guide to fiber optic testing second edition volume 1 by j. An outside plant installer will have an otdr on hand to test every splice. Otdr testing procedure the otdr test process is dependent on the equipment type and the fiber optic cable run being tested, as well as the objectives of the test.
Lanscape solutions recommended fiber optic test guidelines. This users manual explains the features, operating procedures, and handling precautions of the. Always avoid looking directly at unconnected end of optic fiber in testing and. The otdr is also commonly used to create a picture of fiber optic cable when it is newly installed. Optical power meter rx led laser tx tier 1 insertion loss test procedure 1 set reference light source tx opm rx.
Standards and recommendations for fiber optic systems. Mtp200 series users manual shineway technologies, inc. The optical time domain reflectometer, or otdr, is an essential instrument for characterizing long outside plant fiber optic cables. Later, comparisons can be made between the original trace and a. It calls attention to a procedure, practice, or the like, which, if not correctly performed or. Installing and testing fiber optics the fiber optic association. To fully understand the meaning of an otdr measurement, users must. Otdr testing an optical timedomain reflectometer or otdr is a sophisticated test instrument used to probe the characteristics of long optical fibers. Otdr testers tp 700 optical time domain reflectometer. Receive cable tail cord a test cable used to terminate the far end of the link under test that is long enough for the otdr to measure the loss of the last connection. They work by injecting a very brief pulse of light into one end of a long optical fiber, then monitoring any light received at that same end of the fiber. Demystifying fiber test methods mpo configurations. The otdr is the only instrument capable of verifying inline splices on concatenated fiber optic cables and locating faults.
1415 1017 245 1115 1359 1133 470 1195 1498 750 989 1238 1438 803 919 1024 282 1571 615 1593 1063 901 287 1288 703 1065 1535 19 417 311 1558 1248 520 232 93 967 1334 253 893 1211 1425 1359 119 1192 404